Key Concepts:
•When the event rule is true and valid, a push notification is send to the mobile device of selected users.
•The users must connected to the Cloud through the mobile application to receive push notifications.
•Mobile clients v20.1 or later are required to receive push notifications.
•Users can receive push notifications from multiple Sites that are connected to their account.
•Users can toggle or suppress notification on their mobile device.
Begin When:
The Begin When setting appears only for supported events, with options varying by event type.
•When event occurs is the moment an instantaneous events occurs.
•When event starts is the moment the event rule became true and valid.
•When event stops is the moment the event rule was no longer true and valid
To:
Select the users who will receive the Open Layout action:
1.Click on the To Users data field to open the selection dialog.
2.Slide the Show all users switch to display individual users – only groups are shown by default.
3.The search box will filter available users and groups by name.
4.Select/deselect users and groups until the event rule is configured as intended.
NOTE: Selected users without cloud accounts are shown in red text.
Header: (optional)
•Provide custom text that will replace the Site generated notification header.
•Find available metadata by staring with a open curly bracket {.
Body: (optional)
•Provide custom text that will replace the Site generated notification body.
•Find available metadata by staring with a open curly bracket {.
•Selecting Add Source Device name to Body to increase the information provided to users.
Dialog Controls:
•Click Apply to update the event rule and keep the dialog open.
•Click OK to save settings and close the dialog.
•Click Cancel or use the close window control to discard any changes not applied and close the dialog.
Interval of Action:
To avoid overlapping actions, enable the interval of action and set the Once in duration to be longer than the execution time of the action.
•Move the slider switch to enable or disable the interval of action control.
•If enabled, a numerical value for the interval of action and a unit of measurements is required.
•Users without an accurate email address set in their profile are unable to receive Email notifications.