Key Concepts:

When the event rule is true and valid, a HTTP(S) Request is sent to a Site endpoint.

This method allows an event to make an internal Site API call.

Begin When:

The Begin When setting appears only for supported events and the following options will varying by event type:

When event occurs is the moment an instantaneous events occurs.

When event starts is the moment the event rule became true and valid.

When event stops is the moment the event rule was no longer true and valid.

Endpoint:

Enter the Site endpoint that will receive the content of the request.

Method:

Select the method to be sent:

oGET

oPOST (default)

oPUT

oPATCH

oDELETE

Content:

Enter the complete body of the request to be delivered to the URL, including any Event Field Metadata.

Interval of Action:

To avoid overlapping actions, enable the interval of action and set the Once in duration to be longer than the execution time of the action.

Move the slider switch to enable or disable the interval of action control.

If enabled, a numerical value for the interval of action and a unit of measurements is required.

Dialog Controls:

Click Apply to update the event rule and keep the dialog open.

Click OK to save settings and close the dialog.

Click Cancel or use the close window control to discard any changes not applied and close the dialog.