Automatic failover allows a server to automatically discover and attach cameras from a failed server. The failed and the functional server(s) must be within the same System. When a server power, networking failure, or failure to the last remaining storage drives occurs, devices are transferred to the first available failover-enabled server, and the Client is automatically reconnected. A 30-day grace period is granted to the failover-enabled server to allow the cameras to continue recording seamlessly (see Expired and Invalid License Keys).
Failover requires that at least two servers be enabled. However, to adequately protect a System, all servers should be failover-enabled. This is to protect any given server and because failover success depends on the device capacity of the individual servers.
For example, in a System with three servers, server A has maximum capacity of 128 cameras and is actively recording 80 cameras, server B has a maximum capacity of 128 cameras and is actively recording 64 cameras, and server C has a maximum capacity of 128 cameras and is actively recording 88 cameras. Therefore server A has a failover capacity of 48 devices (128 -40), server B has a failover capacity of 64 devices (128-64), and server C has a failover capacity of 40 devices (128-88).
If any one of these servers were to fail, both the other servers would be required to capture all of the disconnected devices. For example, a failure of server A would require space for 80 devices. Server B has failover capacity for 64 devices and server C has failover capacity for 40 devices, so neither alone would be sufficient (64 + 40 ≥ 80). Similarly, A (48) plus C (40) are needed for the 64 cameras on B if it were to fail, and A + B are needed for the 88 devices on C (48 + 64 ≥ 88).
Failover takes approximately 1 minute in the instance of a network or power failure. Archive playback from the failed server will not function until it is back online.
To configure failover on a server
The failover priority setting is a system-wide option and is synced across all servers in the System. When failover is enabled, if the last remaining main storage location is invalid or failed, failover is triggered automatically.
1.Right click on the desired server in the Resource Panel and choose Server Settings.
2.In the General tab of the Server Settings dialog, enable Failover.
3.Enter the maximum number of cameras that can be attached to the server (128 maximum on Core i3 or above CPUs, 12 maximum on ARM CPUs).
4.Click Apply or OK.
5.Repeat steps 1 – 4 to enable additional failover servers.
It is also possible to establish a failover priority for individual cameras, so that the most important streams will be transferred first, lower priority cameras after that, and inessential devices can be set to not transfer at all.
To configure failover priority for a specific camera
By default all cameras in a System are set to "Medium" failover priority. To turn off the failover feature for a given cameras, set it to "Never".
1.In the General tab of the Server Settings dialog, click Failover Priority.
2.Expand each server to list the attached cameras and reveal the Failover Priority checkbox. The default setting is medium.
3.Check the desired camera and click one of the buttons – Never, Low, Medium, or High – at the bottom to set the desired priority.
4.Repeat steps 2 – 3 for all cameras that should be given a failover priority.
5.Click OK to apply changes in the Failover Priority dialog.
6.Click OK or Apply in the Server Setting dialog.